Brand: OMRON
Product model: E5EN-R3H01T-FLK-N
Name: OMRON E5EN-R3H01T-FLK-N User's Manual Digital Temperature Controller Manual
Sort: User's Manual
File language: English
File size: 4.04MB
Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling E5EN-R3H01T-FLK-N PDF.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input E5EN-R3H01T-FLK-N
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port,, is adopted,
Visual angle, contrast can be improved E5EN-R3H01T-FLK-N PDF E5EN-R3H01T-FLK-N Manual.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors E5EN-R3H01T-FLK-N PDF.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output OMRON User's Manual.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. The detection type of the radiation area.
Test area size: 77mm.
Minimum detection object: 0 OMRON User's Manual. 15mm (cube). Sensing method: Diffuse-reflective.
Connection method: Pre-wired (2 m).
Sensing distance: 5 to 100 mm (wide view).
Model: PNP output .
The Standard for Photoelectric Sensors,
with a Secure Tracck Record of One,
Million Sold Yearly E5EN-R3H01T-FLK-N User's Manual.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models OMRON User's Manual.
Mechanical axis and optical axiss offset of less than ±2 E5EN-R3H01T-FLK-N Manual. 5° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light.
Related products
OMRON
Foundation type temperature controller
E5EN-R3HT-W-N
OMRON Foundation type temperature controller E5EN-R3HT-W-N
Size: 48 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5EN-R3HHBT-W-N
OMRON Foundation type temperature controller E5EN-R3HHBT-W-N
Size: 48 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5EN-R3HL-N
OMRON Foundation type temperature controller E5EN-R3HL-N
Size: 48 x 96mm. Ontology: terminal type, ana
OMRON
Foundation type temperature controller
E5EN-R3HT-N
OMRON Foundation type temperature controller E5EN-R3HT-N
Size: 48 x 96mm. Ontology: terminal type, tem