Cable with connector (1 to 2) /G79-O_C-_, G79-I_C-_.
L size: A, 1000mm; B, 750mm.
Input use.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable G9SX-GS226-T15-RC PDF. Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes
G9SX-GS226-T15-RC
Type: Screw mounting.
Applicable load: 35 A, 200 to 480 VAC.
Number of pole: 3.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work G9SX-GS226-T15-RC PDF.
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track G9SX-GS226-T15-RC PDF.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA,, and EN standards (TÜV certification) G9SX-GS226-T15-RC Manual. Mounting type: PCB mounting.
Contact form: 4PST-NO.
PCB terminals.
A High-capacity, High-dielectric-strength,
Multi-pole Relay Used Like a Contactor OMRON USER'S MANUAL.
Miniature hinge for maximum switching power for motor loads,
as well as resistive and inductive loads.
No contact chattering for momentary voltage drops up to 50%,
of rated voltage.
Withstanding more than 4 kV between contacts that are differ,
ent in polarity and between the coil and contacts OMRON USER'S MANUAL.
Flame-resistant materials (UL94V-0-qualifying) used for all in,
sulation material.
Standard models approved by UL and CSA. Main contacts: 3PST-NO.
Auxiliary contact: SPST-NC.
Number of input channels: 2 channels.
Reset mode: Auto-reset.
Input type: Inverse.
Rated voltage: 24 VAC/VDC OMRON USER'S MANUAL.
Ultra Slim Safety Relay Unit.
Models of width 17.5 mm available with 2 or 3 poles. Models.
of width 22.5 mm with 3 poles also available.
Conforms to EN standards. (TÜV approval).
DIN track mounting possible. Insulation method: Photocoupler.
Operation indicator: Yes (yelllow) G9SX-GS226-T15-RC USER'S MANUAL.
Zero cross function: No.
Applicable output load: 150 A, 180 to 480 VAC.
Rated input voltage: 5 to 24 VDC.
High-power, Load-control SSRs with.
High Current of 75 or 150 A and High.
Voltage of 240 or 480 VAC.
RoHSS compliant G9SX-GS226-T15-RC Manual.
Models also available with no zero cross.
Replaceable power elements.
Conforms to cULus standards and EN standards (TÜV certification).