Type: H5CZ.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s, 0.1 to 999.9 s,
1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min, 1 to 9999 min,
1 min to 99 h 59 min, 0 H7AN-R6D PDF. 1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2
H7AN-R6D
External connections: 8-pin socket H7AN-R66D PDF H7AN-R6D Manual.
Inputs: Signal, Reset (NPN inputs).
Outputs: Contact output (time-limit SPDT).
Supply voltage: 12 to 24 VDC/24 VAC.
Easy to Use and Easy to Read.
Basic Features.
Character height of 10 mm for better readability.
Operation is simplified by the Up/Down Keys for each digit on 4-digit H7AN-R6D PDF.
Safety and Reliability.
Power supply circuit and input circuits are isolated for safety and reliability.
Set value limit function prevents unexpected operation of output devices.
caused by setting mistakes.
Output counter function helps in managing the service life of the Timer or,
the load OMRON User's Manual.
Other Features.
Models with instantaneous contact output.
Waterproof, dust-proof structure (UL508 Type 4X and IP66).
Key protection. Display type: UP display timer (increments form 0 to the set time).
Output type: Contact output (SPDT).
Pin type: 11-pin.
Memory backup: provided OMRON User's Manual.
Supply voltage: 100 to 240 VAC.
Rated time: 1 s to 99 min 59 s(See note 3.).
Miniature DIN-sized (48 x 48 mm) Quartz.
Timer with Abundant Series Versions.
Series version covver a wide range of rated times; 9 H7AN-R6D User's Manual. 999 s,
99.99 s, 999.9 s, 99 min 59 s, and 99 hrs 59 min.
Selection of elapsed time indication, remaining time indication,
contact output, and transistor output types to suit requirements OMRON Usser's Manual H7AN-R6D Manual.
Power supply freely selectable within a range of 100 to,
240 VAC, as well as 12 to 48 VDC.
Certified for UL and CSA safety standards.