Appearance: circular shell embedded R2.
Static type reverse electric relay K2WR type.
Reverse power relay for household and marine generator.
A high precision power detection can be performed by the analog time division multiplier K3GN-NDT1-FLK PDF.
Through the rated voltage of the switch, adjust the current simulation of variable,
Can correspond to the rated value of all generators.
Due to the instant start in contact, the response difference is minimal,
Position detection with high accuracy
K3GN-NDT1-FLK Sharing with voltage input, no need to control the power supply.
Because it is static, so the anti vibration impact ability, action stability K3GN-NDT1-FLK PDF.
Equipped with easy to manage and maintain the boot display with LED. Rated input voltage: 3-phase 3-wire mode, 200, 220, 230, or 240 VAC.
Ideal for Monitoring 3-phase Power Supplies.
for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor undervoltages, overvoltages, voltage asymmetry, phase,
sequence, and phase loss in three-phase three-wire circuits with one unit K3GN-NDT1-FLK PDF.
One SPDT output relay, 5 A at 250 VAC (resistive load).
World-wide power specifications supported by one unit.
(Set with a rotary switch.).
Relay status can be monitored using LED indicator OMRON User's Manual. Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: ccommunication; RS-232C; NPN open collector (HH, H, PASS, L, LL) K3GN-NDT1-FLK Manual.
96 (W) * 48 (H * 95mm) depth OMRON User's Manual.
Power supply voltage: AC/DC24V.
High speed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations OMRON User's Manual.
Series of DeviceNet type.
The depth (panel below) is only 95mm ultrashortPower supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phasee control, and cyclic control K3GN-NDT1-FLK User's Manual.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3GN-NDT1-FLK Manual.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).