Input type: DC voltage input type.
Output type: BCD+ transistor; -; NPN open collector (5 bit output +HH, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K3HB-SSD-AT11 PDF.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
K3HB-SSD-AT11
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend K3HB-SSD-AT11 PDF.
External event input can be applied to a variety of measurement and identification situations.
DeviIdeal for Monitoring 3-phase Power.
Supplies for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor overvoltages and undervoltages for three-phase,
3-wire or 4-wire power supplies K3HB-SSD-AT11 PDF.
DIP switch setting for 3-phase 3-wire or 3-phase 4-wire,
power supply.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Separate outputs possible for overvoltages and,
undervoltages.
World-wide power specifications supported by one Unit,
(switchable using DIP switch) OMRON User's Manual.
Relay status can be monitored using LED indicator. Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Linnearity: voltage; NPN open collector (HH, H, PASS, L, LL) OMRON User's Manual K3HB-SSD-AT11 Manual.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display OMRON User's Manual.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event inputTime specification: Inverse type.
Current setting range: 2 to 8 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K3HB-SSD-AT11 User's Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-SSD-AT11 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.