Power ratings: 480 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 48 V.
Output current: 10 A.
Boost Current: 12 A.
Reliable and Easy Operation-Worldwide Power Supply SE-K2AN PDF.
Resistant in tough environments.
Easy and fast installation.
The most compact class on the market.
Universal input for worldwide applications:
100 to 240 VAC (85 to 264 VAC).
DC input can be available: 90 to 350 VDC
SE-K2AN
Possible for 2-phase input usage.
Wide operation temperature range: –40 to 70 °C.
Power Boost function at 120%.
Safety standards:
UL508/60950-1, CSA C22.2 No. 107.1/60950-1 SE-K2AN PDF.
EN50178, EN60950-1.
Lloyd’s standards, EN60204-1 PELV.
Safety of Power Transformers: EN61558-2-16.
ANSI/ISA 12.12.01 (excluding 480-W models).
CSA C22.2 No.213 (excluding 480-W models).
15-W,30-W, and 60-W models conform to.
UL Class 2 output Standards.
EMS: EN 61204-3.
EMI: EN 61204-3 Class B SE-K2AN PDF.
Three years Warranty *1. Economic type power supply S8JC-Z additional models,
The new power S8JCC-ZS has a CE certification mark to market SE-K2AN Manual.
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time OMRON User's Manual. Capacity: 240 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Maximum cutoff output current (per branch): 3.8 A.
Total output current: 10 A.
Number of output branches: 6 branch outputs.
Communications functions: None.
Parameter settings: Not changeable OMRON User's Manual.
A New Type of Power Supply That.
Provides Safety and Maintainability.
240- and 480-W power supplies with and digital circuit,
protectors in a single package.
Each branch output tripping current value can be easily,
set at 0.1-A increments.
Startup and shutdown sequence control included OMRON User's Manual.
Various monitor displays and alarms (output voltage,
output current, maintenance forecast monitor,
temperature).
Conforms to UL Class 2.
Mounts to DIN Rail. Terminal/mounting: Plug-in/DIN rail via socket.
Control voltage: 100/110/120 VAC.
Overcurrent detection: Insstantaneous type, W/start-up lock SE-K2AN User's Manual.
Solid-state, Plug-in Current Sensor.
Applicable to motor overcurrent protection and 3-phase AC current detection.
Inverse-type, start-up lock type, and instantaneous type over,
current sensors avvailable SE-K2AN Manual.
Instantaneous type under current sensor available.
Plug-in design simplifies installation, removal, and wiring.
DIN sized (48 mm x 96 mm).