Type: SGDH type drive.
Capacity: 50W.
Voltage: single phase 110V.
Mode: torque, speed, position.
Test platform for mutual feedback of servo driver and motor SGMCS-16DDC11 PDF.
Test platform with adjustable analog load.
A test platform with an actuator that has no load is used.
Test platform for driving the inherent load by using motor.
Test platform using on line test method.
This test system is composed of three parts,
Were measured servo driver - motor system, the system inherent load and host computer
SGMCS-16DDC11
The host computer sends the speed command signal to the servo driver, and the servo system starts to runn according to the instruction SGMCS-16DDC11 PDF SGMCS-16DDC11 Manual.
In the course of operation, the running data of the servo system is collected by the host computer and the data acquisition circuit,
And carries on the preservation, the analysis and the display to the data. Sigma -V series servo motor SGMGV.
Rated output: 11kw SGMCS-16DDC11 PDF.
Power supply voltage: AC400V.
Serial encoder: 20 bit absolute value type (standard).
Design sequence: standard.
Shaft end: straight shaft, without keyway (standard).
Optional: no matching.
A variety of mechanical feed shaft drive (high speed feed).
Variety is complete (300W ~ 15kW, with hold brake) Yaskawa USER'S MANUAL.
Equipped with a high resolution serial encoder (20 bit).
Standard using IP67.
Use example:
Machine tool。
Transport machinery.
Handling machinery。
Food processing machinery.
Rating and specifications:
Rated time: continuous.
Vibration level: V15.
Insulation resistance: DC500V, 10M, or above Yaskawa USER'S MANUAL.
Using ambient temperature: 0 ~ 40 degrees C.
Excitation mode: permanent magnet type.
Installation method: flange type.
Heat resistance grade: F.
Insullation withstand voltage: AC1500V 1 minutes (200V), AC1800V 1 minutes (400V) SGMCS-16DDC11 USER'S MANUAL.
Protection mode: fully enclosed self cooling type IP67 (except shaft through part) Yaskawa USER'S MANUAL.
The use of environmental humidity: 20 ~ 80%% (not dew) SGMCS-16DDC11 Manual.
Connection mode: direct connection.
Rotation direction: clockwise direction (CCW) rotation at the load side under the direction of rotation