Control power supply voltage: 48 VDC.
Input: DC, Input voltage range, 10 to 300 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) .
Detect three-phase AC current for under and/or overcur,
rent using current converter
GLS-S1-L
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F) GLS-S1-L.
LED operation indicator.
UL/CSA approval (SDV-F@). Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: L-shaped/L-shaped.
Cable diameter: 6.0 mm dia.
No. of cable cores: 4.
Cable core cross sectional area: 0.5 mm.
Cable length: 2 m.
DC: Minimum order, 5.
UL-listed: Yes.
Water- and Environment-resistive FA GLS-S1-L.
Connectors Save Wiring and Maintenance Effort .
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Model : C500-FZ001.
C500-FZ Special I/O Unit Fuzzy Logic Unit C500-FZ001.Appearance: Standard.
Sensing method: Throughbeam type(with slot).
Connecting method: Connector(4 poles).
Sensing distance: 5 mm (slot width).
Output configuration: Dark-ON/Light-ON (selectable).
Indicator mode: No incident light.
Model: NPN output.
Global Standard Slot-type.
photomicrosensors with 50- to,
100-mA direct switching capacity.
Seeries includes models that eenable switching between,
dark-ON and light-ON operation GLS-S1-L.
Response frequency as high as 1 kHz.
Easy operation monitoring with bright light indicator.
Wide operating voltage range: 5 to 24 VDC.
Models in which the light indicator turns ON for ddarrk-ON,
operation are also available GLS-S1-L.
A wide range of variations in eight different shapes.
Flexible robot cable is provided as a standard feature.
GLS-S1-L Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=GLS-S1-L&select=5