Internal I/O common: NPN.
I/O indicators: LED display (yellow).
Unit power supply current consumption: 120 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 140 g max.
Expansion functions: No.
Short-circuit protection function: Available at input,
section only (Operates at 50 mA/point min MY4J AC110/120. )
Easy wiring using industry standard,
e-CON connectors
MY4J AC110/120
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing MY4J AC110/120.
Selectable node address setting methods:
setting with rotary,
switch and with tool software .
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output MY4J AC110/120.
Control mode: standard or heating cooling .
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through thhe support software (VVer MY4J AC110/120.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the frronnt of the communication MY4J AC110/120.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
MY4J AC110/120 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MY4J AC110/120&select=5