Actuator: Plunger.
Conduit openings: M20.
1NC/1NO (Snap-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts .
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever
E2G-M18KS07-WS-D2-T
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties E2G-M18KS07-WS-D2-T.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13) .
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling E2G-M18KS07-WS-D2-T.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function .
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-422.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the suppport software (VVer E2G-M18KS07-WS-D2-T.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the frronnt of the communication E2G-M18KS07-WS-D2-T.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
E2G-M18KS07-WS-D2-T Operation manual / Instructions / Catalog download link: