Size: 48 x 24mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: - .
Event input: 2 points.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance
F3SJ-A0745N30
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition F3SJ-A0745N30.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance .
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set F3SJ-A0745N30.
It can be easily set by CS-Thermo (sold separately). Setting range: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and undervoltages.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Type: Device Net.
The DeviceNet Communication Unit That.
Simplifies Managing Sensor Settingss F3SJ-A0745N30.
ON/OFF signals and incident light levels can be sent to the host,
PLC without any need for programming (DeviceNet communications,
slave functionality) .
Threshold values and function settings can be read, written,
or taught (using the Message Communications functtioon) F3SJ-A0745N30.
Simply connect the communication cables and slide the Amplifiers,
from the side for wire-saving.
Up to 16 Sensor Amplifiers can be connected.
F3SJ-A0745N30 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=F3SJ-A0745N30&select=5