32 point connector for pressing flat cable (40 pin connector.Series Name: A951GOT.
Size: 6 inches.
Resolution: 320 * 240.
Display equipment: high brightness TFT color display A1S62DA PDF.
Display color: 256 color.
Power supply: DC24V.
Built in BUS Q communication interface.
Memory card: 3M.
China is the world''s biggest market for human machine interface,
But it is not the highest sales market in the world,
This shows that the low-end user interface in China has a large share of
A1S62DA
In recent years, the rapid development of national brands, to take a low price and other strategies, is a massive attack on the low end of the market,
Has occupied the dominant position in the low-end market, has won the recognition of the majority of users A1S62DA PDF.
International brands are also gradually developing its economic products, in order to seize the share of the low-end market.
Therefore, in the low-end market steady,
The overall performance of the domestic human machine interface manufacturers showing a rapid growth of the state A1S62DA PDF. Remote I/O controller, optical fiber.
How to choose MITSUBISHI PLC.
MITSUBISHI PLC options include the choice of MITSUBISHI PLC models, capacity, I/O module, power, etc..
MITSUBISHI PLC distribution I/O points and designn MITSUBISHI PLC peripheral hardware circuit
Draw the I/O point of the PLC and the input / output device connection diagram or the corresponding table,
This part also can be carried out in second steps MITSUBISHI User's Manual A1S62DA Manual .
Design PLC peripheral hardware circuit.
Draw the electrical wiring diagram of the other parts of the system,
Including the main circuit and the control circuit does not enter the PLC, etc MITSUBISHI User's Manual. .
The electrical schematic diagram of the system composed of I/O PLC connection diagram and PLC peripheral electrical circuit diagram.
So far the system''s hardware electrical circuit has been determined MITSUBISHI User's Manual. GI fiber optic cable.
Double circuit.
MELSECNET (II) (remote I/O station).
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC initialization proceduure A1S62DA User's Manual. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program arre: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc A1S62DA Manual . .