RS-232 2 channel.
Transmission speed: 2 channels.
At the same time the use of 115.2kbps may.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register A2ACPUP21 PDF.
And then combine the data and the program with CPU.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive
A2ACPUP21
Semiconductor circuit with memory function.
System program memory and user memory.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation A2ACPUP21 PDF.
Read only memory. Manufacturers use, content can not be changed, power does not disappear. Cable length 3M; used in A6TE2-16SRN.Cable length: 20.6 meters.
Small CPU long distance connecting cable A2ACPUP21 PDF.
For QnAS/AnSCPU/ motion control and GOT connection.
For connection between A7GT-CNB and GOT.
Combination A8GT-EXCNB and A8GT-C_BS. Analog RGB input system.
Applicable model: A985GOT-V. A pack of 10.
Applicable models:
AJ65VBTS - - - type.
AJ65VBTCE - - - type A2ACPUP21 Manual.
AJ65VBTCU - - - type.
AJ65ABTP - - - type MITSUBISHI Programming Manual .
AJ65VBCU- - type. Input and output points: 480 points.
Program capacity: 7K step.
Basic command processing speed: 4.4 ~ 5.6us.
Power supply: input AC100 ~ 120/200 ~ 240V/ output 2A DC24V, 0.5A DC5V.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way MITSUBISHI Programming Manual . Easy maintenance.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words MITSUBISHI Programming Manual . Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load currrent and voltage A2ACPUP21 Programming Manual .
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is discoonnected from the load A2ACPUP21 Manual.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.