Input type: DC input, positive public end / negative public end.
Input points: 16 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA A2CCPUC24 PDF.
Output form: transistor output, leakage type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 1 line /1 line type
A2CCPUC24
40 pin connector type (FCN connector type).
Through the 40 pin connector type (FCN connector type) can be connected to a variety of devices.
Can be installed along the 6 direction.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong A2CCPUC24 PDF.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness A2CCPUC24 PDF.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer. Axis of control: 1.
A1SD70 is a kind of voltage output type single axis positioning control module,
Equipped with a servo motor can form a closed loop control system of precise positioning MITSUBISHI Programming Manual.
Its fastest positioning speed up to 400Kpps, the location of the 32 bit binary number (with a symbol bit).
Positioning units according to the specific application settings, such as the number of pulses, millimeters, inches or degrees MITSUBISHI Programming Manual. Input and output points: 1024 points.
Input / output data points: 8192 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:0.20.
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power suupply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure MITSUBISHI Programming Manual A2CCPUC24 Manual .
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a meeasure of how much the user application can store the number of indicators A2CCPUC24 Programming Manual.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words A2CCPUC24 Manual . Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.