LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI A2USCPU Programming Manual (Dedicated Instructions) PDF

MITSUBISHI A2USCPU Programming Manual (Dedicated Instructions) PDF

Brand: MITSUBISHI
Product model: A2USCPU
Name: PLC
Sort: Programming Manual (Dedicated Instructions)
File language: English
File size: 17.11MB
Multi axis positioning controller.
Coaxial data communication line function.
Program capacity: Max 60K step.
Input / output points: 1920 points.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor A2USCPU PDF.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal A2USCPU
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc A2USCPU PDF. .
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points A2USCPU PDF. 34 point with the wiring transformation adapter 2 line type 16 point input CC-Link unit installation special connection conversion adapterThe A1SP60 pulse capture module is a 16 point DC24V input module,
Can be used as a general input module,
Can also be used as a pulse capture module,
Pulse capture function makes the input signal width in the sequence can be as short as 0 MITSUBISHI Programming Manual. 5ms,
Once there is a pulse signal input, the state is memory,
A1SP60 to ensure that the control process at least once again to control the state of the memory of the operation,
Input can be set to 4 blocks,
Each block can be set to a general function or pulse capture function MITSUBISHI Programming Manual. Input type: DC input, negative public end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 3 wire.
Sensor connector type (E-CON type).
Using industry standard E-CON type MITSUBISHI Programming Manual.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Input points: 16 points.
Input voltage and current: 240V ~ 10mA AC100.
Input response time: 35ms.
16 point /1 a public side.
Output points: 12 points.
Output voltage: AC100 ~ 240V.
OFF leakage current: 3mA.
Output response time: 0.5Hz+1ms.
Output type: bidirectional thyristor output.
8 point /1 a public end, 4 points / a public end.
36 point terminal station.
With short circuit protection.
With the surge absorber.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil soleenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A2USCPU Manual .
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal A2USCPU Programming Manual.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points A2USCPU Manual .
Related products
MITSUBISHI
General purpose CPU
Q00UCPU
MITSUBISHI General purpose CPU Q00UCPU
nput / output points: 1024 points. Numer of
MITSUBISHI
With Ethernet CPU
Q100UDEHCPU
MITSUBISHI With Ethernet CPU Q100UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
CPU unit
A2ACPU
MITSUBISHI CPU unit A2ACPU
Input and output points: 512 points. Input /
MITSUBISHI
High performance CPU
Q12HCPU
MITSUBISHI High performance CPU Q12HCPU
Program capacity: 124 K step. Input / output