LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI A3NCPU Programming Manual (Dedicated Instructions) PDF

MITSUBISHI A3NCPU Programming Manual (Dedicated Instructions) PDF

Brand: MITSUBISHI
Product model: A3NCPU
Name: PLC
Sort: Programming Manual (Dedicated Instructions)
File language: English
File size: 17.11MB
Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA A3NCPU PDF.
Output form: transistor output, leakage type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/0.1A.
External connection: 1 line /1 line type.
40 pin connector type (FCN connector type) A3NCPU
Through the 40 pin connector type (FCN connector type) can be connected to a variety of devices.
Can be installed along the 6 direction.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong A3NNCPU PDF A3NCPU Manual .
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness A3NCPU PDF.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer. Input and output points: 1024 points.
Input / output data points: 1024 points.
Program capacity: 14K MITSUBISHI Programming Manual.
Basic command processing speed (LD command) s:1.0.
AnNCPU command processing time and ACPU compare to 10-20% high speed processing.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units MITSUBISHI Programming Manual. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this struucture MITSUBISHI Programming Manual A3NCPU Manual A3NCPU Programming Manual.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Related products
MITSUBISHI
CPU unit
Q2ASCPU
MITSUBISHI CPU unit Q2ASCPU
Input and output points: 512 points. Input /
MITSUBISHI
High performance CPU
Q02CPU
MITSUBISHI High performance CPU Q02CPU
Program capacity: 28K step. Input / output po
MITSUBISHI
CPU unit
Q2ASHCPU
MITSUBISHI CPU unit Q2ASHCPU
Input and output points: 512 points. Input /
MITSUBISHI
CPU unit
A2USCPU
MITSUBISHI CPU unit A2USCPU
Input and output points: 512 points. Input /