LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI A73CPUP21-S3 Programming Manual (Dedicated Instructions) PDF

MITSUBISHI A73CPUP21-S3 Programming Manual (Dedicated Instructions) PDF

Brand: MITSUBISHI
Product model: A73CPUP21-S3
Name: PLC
Sort: Programming Manual (Dedicated Instructions)
File language: English
File size: 17.11MB
Input and output points: 2048 points.
Input / output data points: 2048 points.
Program capacity: 30K.
Basic command processing speed (LD command) s:1.0 A73CPUP21-S3 PDF.
Optical data communication line function (GI cable).
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read A73CPUP21-S3
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh A73CPUP21-S3 PDF.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode A73CPUP21-S3 PDF.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words MITSUBISHI Programming Manual A73CPUP21-S3 Manual . PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4. Output points: 8 points.
Output voltage and current: DC12/24V MITSUBISHI Programming Manual.
Output response time: 2ms.
8 point /1 a public side.
Output form: transistor output, leakage type.
24 point terminal station.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations MITSUBISHI Programming Manual.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc..
MITSUBISHI PLC program simuulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of thee program A73CPUP21-S3 Manual A73CPUP21-S3 Programming Manual.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.
Related products
MITSUBISHI
Moving CPU unit
A73CPUP21-S1
MITSUBISHI Moving CPU unit A73CPUP21-S1
Multi axis positioning controller. Optical da
MITSUBISHI
Melsecnet interface module
A1SJ71AP21-S3
MITSUBISHI Melsecnet interface module A1SJ71AP21-S3
PLC station distance: 2Km. Cale type: GI-50/
MITSUBISHI
Moving CPU unit
A73CPUR21
MITSUBISHI Moving CPU unit A73CPUR21
Multi axis positioning controller. Coaxial da
MITSUBISHI
Moving CPU unit
A73CPU
MITSUBISHI Moving CPU unit A73CPU
Multi axis positioning controller. Program ca