LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI AJ71E71N-B5 User's Manual PDF

MITSUBISHI AJ71E71N-B5 User's Manual PDF

Brand: MITSUBISHI
Product model: AJ71E71N-B5
Name: Ethernet Interface Module
Sort: User's Manual
File language: English
File size: 14.88MB
Output points: 16 points.
Voltage: DC24V/AC240V, 2A/1 point, 16A/ all points.
OFF leakage current: 0.1mA.
Output type: relay output.
Response time: 12ms AJ71E71N-B5 PDF.
All points of independence.
38 point terminal station.
With the surge absorber.
CE certification.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor AJ71E71N-B5
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal AJ71E71N-B5 PDF.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points AJ71E71N-B5 PDF.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of vaarious types of machinery or production process MITSUBISHI User's Manual AJ71E71N-B5 Manual.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points MITSUBISHI User's Manual MITSUBISHI User's Manual. 4 channels.
Measurement range: 0.000-3550.000mm.
Resolution: 0.025mm.
Ultrasonic linear proportional connection.
When communicating in the PLC network of MITSUBISHI,
There is no sense of difference and discontinuity in the network,
Can carry on the remote monitoring, modification, debugging and other work of data communication and program,
Without taking into account the level and type of network.
MELSECNET/H and CC-Link use the way of loop communication,
Periodically automatically send and receive messages,
DDoes not require specialized data communication procedures,
Simple parameters can be set AJ71E71N-B5 User's Manual.
MELSECNET/H and CC-Link are used to transmit and receive the broadcast mode,
This can be done on the network data sharing.
For the use of Etthernet, MELSECNET/H, CC-Link network,
Can set the network parameters and various functions, simple and convenient in the Developer GX software screen AJ71E71N-B5 Manual.
Related products
MITSUBISHI
Network module
AJ71E71N-B5T
MITSUBISHI Network module AJ71E71N-B5T
Ethernet network module 10BASE-T/10BASE5. Con
MITSUBISHI
Network module
AJ71E71N-B5
MITSUBISHI Network module AJ71E71N-B5
10BASE5. When communicating in the PLC networ
MITSUBISHI
Ethernet module
AJ71QE71N-B5
MITSUBISHI Ethernet module AJ71QE71N-B5
10BASE5. For Q mode. Control layer /MELSECNET
MITSUBISHI
Ethernet module
AJ71E71N-T
MITSUBISHI Ethernet module AJ71E71N-T
10BASE-T Control layer /MELSECNET/10 H is t