MITSUBISHI inverter FR-E720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 15KW.
In order to ensure the reliability of production, all production machinery in the design of power with drive, there is a certain amount of surplus FR-A720-22K PDF.
When the motor can not run under full load, in addition to meet the requirements of power driven,
The surplus torque increases the active power consumption, resulting in the waste of electric energy
FR-A720-22K
Speed control method of fan and pump equipment traditional by regulating the entrance or exit of the baffle, valve opening to regulate air flow and water flow
, the input power is large, and a large amount of energy consumption in the baffle, the valve in the process of closure FR-A720-22K PDF.
When using variable frequency control, if the flow rate is reduced, the speed of the pump or fan can be reduced to meet the requirements. MITSUBISHI inverter series: FR-F840 FR-A720-22K PDF.
Voltage level: three phase 400V.
Power: 2.2kw.
SLD converter rated current: 5.2A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed MITSUBISHI PLC FUNCTION PROGRAMMING MANUAL.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption.
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of tthe motor FR-A720-22K Manual.
Load torque is smaller, can further improve energy efficiency MITSUBISHI PLC FUNCTION PROGRAMMING MANUAL.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 220kw.
SLD converter rated current: 481A MITSUBISHI PLC FUNCTION PROGRAMMING MANUAL.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
The motor efficiency is not changed in the previous optimal excitation control,
At the same time, the newly developed advanced optimal excitation control can obtain larger torque at startup.
No need to adjust the parameters (plus deceleration time or torque, etc.), in a short time to speed up to a certain speed,
Can be carried out to maximize the efficiency of energy-saving drive motor.
The automatic tuning function of the loop constant of the motor is not consistent with the constant of the motor, the motor of other manufacturers, and the length of wiring is too long,
Optimum operating characteristic drrive motor FR-A720-22K PLC FUNCTION PROGRAMMING MANUAL.
In the state of the sensor can not only drive the high efficiency and energy saving motor and PM motor (MM-EFS), but also can drive other companies induction motor and PM motor (permanent magnet synchronous motor).
Othher manufacturers of induction motors, can also be automatically tuned to achieve the best excitation control, thus expanding the use of energy saving FR-A720-22K Manual.