LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI FR-A720-75K PLC FUNCTION PROGRAMMING MANUAL PDF

MITSUBISHI FR-A720-75K PLC FUNCTION PROGRAMMING MANUAL PDF

Brand: MITSUBISHI
Product model: FR-A720-75K
Name: INVERTER
Sort: PLC FUNCTION PROGRAMMING MANUAL
File language: English
File size: 3.53MB
Total points: 10 points.
Input points: 6 points.
Output points: 4 points.
Voltage: AC220V.
Output type: transistor.
Outline dimension: 60*75*90.
MITSUBISHI FX1S series PLC is suitable for the smallest package,
It is the preferred target for low cost users to seek powerful control over a limited range of I/0 FR-A720-75K PDF.
FX1S provides up to 30 I/O points, and can be transmitted through serial communication data,
MT models also have the ability to locate, widely used in a variety of small mechanical equipment FR-A720-75KMITSUBISHI inverter FR-D720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 5 FR-A720-75K PDF. 5KW.
Vector control variable frequency speed control is the practice of the asynchronous motor in the three-phase coordinate system of the stator current Ia, Ib, Ic, through the three-phase to two-phase transformation,
The alternating currentt of Ia1Ib1 is equivalent to a two phase stationary coordinate system, and then is rotated by the rotor field oriented,
Equivalent to the DC current Im1, It1 (Im1 equivalent to DC motor excitation current in synchronous rotating coordinate system;
It1 equal to the armature current proportional to the torque, and then imitate the DC motor control method, to obtain the DC motor control,
The control of asynchronous motor is realized through the corresponding inverse coordinate transformation FR-A720-75K PDF MITSUBISHI PLC FUNCTION PROGRAMMING MANUAL FR-A720-75K Manual. MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 5.5KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible MITSUBISHI PLC FUNCTION PROGRAMMING MANUAL.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used MITSUBISHI PLC FUNCTION PROGRAMMING MANUAL FR-A720-75K PLC FUNCTION PROGRAMMING MANUAL. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced FR-A720-75K Manual.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft.
Related products
MITSUBISHI
16 bit digital output module
FR-A7AX
MITSUBISHI 16 bit digital output module FR-A7AX
Uses: for external BCD or inary digital sign
MITSUBISHI
3 phase 400V converter
FR-A740-250K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-250K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-315K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-315K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 200V converter
FR-A720-75K
MITSUBISHI 3 phase 200V converter FR-A720-75K
MITSUBISHI inverter FR-A720 series. Voltage l