Brand: MITSUBISHI
Product model: FR-A740-45K-C9
Name: INVERTER
Sort: PLC FUNCTION PROGRAMMING MANUAL
File language: English
File size: 3.53MB
Protocol: SLMP, TCP/IP, UDP, SNTP.
Communication mode: full duplex / half duplex.
At the same time can open a few: 4 connection.
Weight: 0.3kg.
Can be low cost will be connected to the FX3 series Ethernet FR-A740-45K-C9 PDF.
Support data monitoring, can monitor the basic unit through the computer browser,
Remote maintenance can be carried out by Works2 GX in a place far from the scene.
Connect FX3SA, FX3S, FX3GA, FX3G, FX3U host, you need to convert the adapter or function expansion board FR-A740-45K-C9 Memory format: EEPROM.
Number of steps: up to 16000 steps can be used.
Battery support: do not.
Method for writing and deleting: the device is installed on the PLC, and is written and deleted by the peripheral device FR-A740-45K-C9 PDF.
Note: built-in extension. Max input / output points: 20 points.
Power supply voltage: 24VDC.
Input points: 12 points.
Output points: 8 points.
Output type: relay.
Power consumption (W): 7.
Weight (kg):0 FR-A740-45K-C9 PDF. 3.
Size (WxHxD) mm:75x90x49.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain MITSUBISHI PLC FUNCTION PROGRAMMING MANUAL.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication MITSUBISHI PLC FUNCTION PROGRAMMING MANUAL.
All equipment is digital input and output point.
The total I/O points are not more than 30 points, and the input points are less than 16, the output points are less than 14.
Its MT series of PLC can drive 2 way servo or stepper, commonly used in the control system for a simple manipulator MITSUBISHI PLC FUNCTION PROGRAMMING MANUAL. "MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V.
Frequency converter capacity: 75KW.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is aa power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions FR-A740-45K-C9 Manual.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is maainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FR-A740-45K-C9 PLC FUNCTION PROGRAMMING MANUAL.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FR-A740-45K-C9 Manual. "
Related products
MITSUBISHI
3 phase 400V converter
FR-A740-400K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-400K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-45K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-45K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-280K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-280K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-11K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-11K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l