RS-232C/RS-422 converterMax input / output points: 24 points.
Power supply voltage: DC24V.
Input points: 14 points.
Output points: 10 points.
Output type: relay FR-A740-5.5K-C9 PDF.
Power consumption (W): 32.
Weight (kg):0.5.
Size (WxHxD) mm:90x90x75.
FX1N series is a very powerful micro PLC, can be extended to up to 128 I/O points,
And can increase the special function module or the expansion board
FR-A740-5.5K-C9
Communication and data link function options make FX1N in the volume, communication and special function modules and other important applications is very perfect.
A PLC unit can output 2 100KHz pulses at the same time,
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute position readout, absolute or relative drive, and special pulse output control FR-A740-5.5K-C9 PDF. Input signal: thermocouple type K or type J.
Applicable PLC:FX1N, FX2N, FX3U, FX2NC (to FX2NC-CNV-IF).
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V) FR-A740-5.5K-C9 PDF.
Thermocouple type temperature sensor input module.
Thermocouple type (K type, J type) temperature sensor input moduule FR-A740-5.5K-C9 Manual.
4 channels can be entered.
Unit can be set to Celsius or fahrenheit.
Resolution is K type 0.4 degree, J type 0.3 degree of high precision MITSUBISHI INSTRUCTION MANUAL. "MITSUBISHI inverter series: FR-A846.
Voltage level: three phase 400V.
Power: 18.5kw.
SLD converter rated current: 47A.
Structure and function: IP55 counterpart.
Type: CA.
Substrate coating: have.
Built in DC reactor.
Easy to operate, simple settings.
We have prepared a series of equipment and functions for you to work in any place to meet the life cycle of the product MITSUBISHI INSTRUCTION MANUAL.
Allegedly, the motor power consumption accounted for about half of the total power generated by manufacturing industry consumption.
How to achieve energy efficiency in the plant without affecting the productivity.
Less energy consumption and more output FR-A800 series inverter will help you to have both fish and bear''s paw"
Parameters and frequency settings can be modified in the program MITSUBISHI INSTRUCTION MANUAL.
Inverter control, for example, by the input signal to trigger the operation of the inverter, based on the operation of the inverter
The status of the signal output, as well as the monitor output and so on, can be customized according to the requirements FR-A740-5.5K-C9 INSTRUCTION MANUAL.
The control of each machine can be done separately by the frequency converter, and the controol of the dispersion is also carried out FR-A740-5.5K-C9 Manual.
Through combining with the real-time clock function can realize the automatic operation (in option FR-LU08). "