Brand: MITSUBISHI
Product model: FR-CV-30K
Name: POWER REGENERATION COMMON CONVERTER
Sort: Instruction manual
File language: English
File size: 2.23MB
Can be isolated to obtain DC24/48/100V, AC100/200V input signal.Protocol: SLMP, TCP/IP, UDP.
Communication mode: full duplex / half duplex.
At the same time can open a few: 4 connection FR-CV-30K PDF.
Weight: 0.3kg.
Connect PLC FX3U/FX3UC to Ethernet.
Support fixed buffer storage, communication connection MELSOFT, through the MC communication protocol, e-mail messages.
When connected to the MELSOFT, through the Works2 PLC can achieve the remote maintenance of GX program FR-CV-30K
Connecting FX3UC, FX3GC requires FX2NC-CNV-IF or FX3UC-IPS-5V. Power: 22kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current FR-CV-30K PDF.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor FR-CV-30K PDF. )
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) Function: simple motion control 4 axis positioning (corresponding to SSCNET III /H).
Input and output points: 8 points MITSUBISHI Instruction manual.
Positioning control via /H III SSCNET.
FX5-40SSC-S is equipped with the corresponding SSCNET III /H 4 axis positioning function module.
Table operation, combinedd with linear interpolation, circular interpolation between the 2 axes, and the connection trajectory control,
Smooth positioning control can be easily realized MITSUBISHI Instruction manual FR-CV-30K Manual .
Positioning function of 8CH high speed pulse input and 4 axis pulse output by FX5U/FX5UC.
In addition, the high speed output can be set through the table, which can be realized through special instructions, which can be used to realize the function of interrupt location, variable speed operation and simple interpolation MITSUBISHI Instruction manual. MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 7.5kw.
SLD converter rated current: 49A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared wiith the FR-A700 series, to reduce the volume of equipment) FR-CV-30K Instruction manual.
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network FR-CV-30K Manual .
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps.
Related products
MITSUBISHI
Parameter unit connection cable
FR-CB201
MITSUBISHI Parameter unit connection cable FR-CB201
Length: 1 meters. Operation panel or paramete
MITSUBISHI
Common DC bus converter
FR-CV-H15K
MITSUBISHI Common DC bus converter FR-CV-H15K
Power: 15kw. Voltage: 400V. There are 100 r
MITSUBISHI
Common DC bus converter
FR-CV-H22K
MITSUBISHI Common DC bus converter FR-CV-H22K
Power: 22kw. Voltage: 400V. There are 100 r
MITSUBISHI
Brake unit
FR-BU2-30K
MITSUBISHI Brake unit FR-BU2-30K
Power: 30kw. Voltage: 200V. Purpose: high fre