Input and output points: 48 points.
DC power supply: DC24V.
Input points: 24 points.
Output points: 24 points.
Output form: transistor output (source) FR-D740-0.4K-CHT PDF.
Weight: 0.85kg.
Input signal voltage: DC24V.
FX2N series expansion unit
Expansion unit is an input and output expansion device with a built-in power supply.
As with the basic unit, the extension unit can be connected to a variety of input and output and special extension equipment
FR-D740-0.4K-CHT
Can connect to FX3GA/FX3G, FX3GE and FX3U.
AC power model, the built-in maximum DC24V 250mA/460mA supply power.
Because all models of FX series are built in high speed counter,
So the high speed control can be realized by the simple procedure FR-D740-0.4K-CHT PDF.
The input of the basic unit is built in the anti jitter filter,
One part as digital filter,
Sensitivity adjustment unit can reach 1ms.
Using high speed counter automatically adjusted to the minimum value.
Through the high cost of the built-in positioning function and the expansion function to increase the number of control axis FR-D740-0.4K-CHT PDF.
Extended function expansion board and special adapter,
Data links and communication with external serial devices. Application: input power line for extended input module.
Length: 1 MITSUBISHI Instruction manual. 0m.
Auxiliary parts for FX3GC and FX3UC. 20 pin connector on both ends of the circular multi-core cable.
Length 3M. Total input and output points: 40 points.
Input points: 24 pooints FR-D740-0.4K-CHT Manual .
Output points: 16 points.
Output type: relay output.
Power supply voltage: DC24V.
Input signal voltage: DC24V MITSUBISHI Instruction manual.
8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type) MITSUBISHI Instruction manual.
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Note recording function, Component annotation can be recorded in the program register.
OOnline program editor, online change the program will not lose the working hours or stop production operation FR-D740-0.4K-CHT Instruction manual.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program FR-D740-0.4K-CHT Manual .