MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 11KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) FR-F740P-5
FR-F740P-5.5K-CHT5K-CHT PDF.
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical.
The inverter drive can be smoothly start (start time longer) FR-F740P-5.5K-CHT PDF.
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is moore than 100%, which can start with full load FR-F740P-5.5K-CHT Manual . Max input / output points: 32 points FR-F740P-5.5K-CHT PDF.
Supply voltage: 100 - 240VAC.
Input points: 16 points.
Output points: 16 points.
Output type: relay.
Power consumption: 40VA.
Weight (kg):0.85.
Size (WxHxD) mm:182x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter MITSUBISHI Instruction manual.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register MITSUBISHI Instruction manual.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to proteect your program MITSUBISHI Instruction manual FR-F740P-5.5K-CHT Instruction manual.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off the continuous scan time FR-F740P-5.5K-CHT Manual .
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).