MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 7.5kw.
SLD converter rated current: 49A.
Structure and function: Standard model FR-F740P-5.5K-CHT PDF.
Type: CA.
Substrate coating: have.
Compatibility with existing models.
Transducer installation size and FR-F700 (P) series of the same, so you do not need to worry about the replacement operation.
(rectifier separation type will vary)
Also, but also through the use of options (FR-A8TAT), FR-F700 (P) series installed control loop terminal station
FR-F740P-5.5K-CHT
Built in 2 PID arithmetic. In the inverter can be PID control of the motor state at the same time, used in the control of the external machine FR-F740P-5.5K-CHT PDF.
No external PID controller is used to control the external machine, so the system cost can be reduced. Power: 11kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed FR-F740P-5.5K-CHT PDF. Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table MITSUBISHI Instruction manual.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor MITSUBISHI Instruction manual.
The installation of thermal relay, to avoid overheating and burn the braking resistor. Total input and output points: 40 pointss FR-F740P-5.5K-CHT Manual .
Input points: 24 points.
Output points: 16 points.
Output type: transistor output.
Power supply voltage: AC100-240V MITSUBISHI Instruction manual.
Input signal voltage: DC24V.
8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Note recording function, Component annotation can be recorded in the program register.
Onnline program editor, online change the program will not lose the working hours or stop production operation FR-F740P-5.5K-CHT Instruction manual.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program FR-F740P-5.5K-CHT Manual .