Analog input points: 4.
Analog output points: 1 points.
Analog input and output expansion module.
With 4CH analog input and 1CH analog output.
With -100mV~100mV micro voltage input range, and therefore do not need a signal converter, etc FX1N-14MT-001 PDF. .
Resolution of 15 bit binary + symbol 14bit, 1bit binary + symbol 1bit high precision analog input and output modules.
Each channel can be used for different input ranges
FX1N-14MT-001
Built in input filter adjustment function, internal operation function, proportion function.
Connect FX3UC, FX3GC, you need to use FX2NC-CNV-IF or FX3UC-1PS-5V. Max input / output points: 32 points FX1N-14MT-001 PDF.
Power supply voltage: 24VDC.
Input points: 16 points.
Output points: 16 points.
Output type: Transistor (source).
Power consumption: 25w.
Weight (kg):0.65.
Size (WxHxD) mm:150x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter FX1N-14MT-001 PDF.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register MITSUBISHI PROGRAMMING MANUAL II.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, runningg on panel / stop switch easy to operate FX1N-14MT-001 Manual.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program MITSUBISHI PROGRAMMING MANUAL II.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time MITSUBISHI PROGRAMMING MANUAL II.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017). MITSUBISHI inverter FR-E720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 5.5KW.
In order to ensure the reliability of production, all production machinery in the design of power with drive, there is a certain amount of surplus.
When the motor can not run under full load, in addition to meet the requirements of power driven,
The surplus torque increases the active power consumption, resulting in the waste of electric energy.
Speed control method of fan and pump equuipment traditional by regulating the entrance or exit of the baffle, valve opening to regulate air flow and water flow
, the input power is large, and a large amount of energy consumption in the baffle, the valve in the processs of closure FX1N-14MT-001 Manual FX1N-14MT-001 PROGRAMMING MANUAL II.
When using variable frequency control, if the flow rate is reduced, the speed of the pump or fan can be reduced to meet the requirements.