Analog input expansion board (2 channel).Max input / output points: 60 points.
Supply voltage: 100 - 240VAC.
Input points: 36 points.
Output points: 24 points FX1N-24MR-001 PDF.
Output type: transistor.
Power consumption (W): 35.
Weight (kg):0.8.
Size (WxHxD) mm:175x90x75.
Rich functionality.
FX series of products are rich in variety, users can be based on cost or application,
Choose the most suitable product
FX1N-24MR-001 Will find a suitable model for the user site.
Terminal row type standard machine with extended input output
Can also be less of a system with analog or communication, etc..
CPU, power supply, input and output integration FX1N-24MR-001 PDF.
Display module or function expansion board can be less installed.
In addition, you can also reduce the input output or special module.
Built in 8000 step EPROM memory.
No battery. Maintenance free.
Overseas oriented products meet all kinds of international standards. MITSUBISHI inverter FR-F7400 series FX1N-24MR-001 PDF FX1N-24MR-001 Manual.
Voltage level: three phase 400V.
Frequency converter capacity: 400KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor MITSUBISHI HARDWARE MANUAL.
Why is the frequency of the inverter voltage proportional to the change?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, the current is not allowed to exceed the rated value, otherwise it will cause the heating of the motor MITSUBISHI HARDWARE MANUAL.
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity. Power: 0.75kw.
Purpose: to suppress the power harmonics MITSUBISHI HARDWARE MANUAL.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FFR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity FX1N-24MR-001 HARDWARE MANUAL.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motorr power used to select the DC reactor FX1N-24MR-001 Manual.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.)