MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 2.2KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible FX1S-10MR-ES/UL PDF
FX1S-10MR-ES/UL
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced FX1S-10MR-ES/UL PDF.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft. Specifications: according to thee connection source FX1S-10MR-ES/UL PDF FX1S-10MR-ES/UL Manual.
Corresponding models: FX3GA, FX3G, FX3GE, FX3GC, FX3U, FX3UC. Power supply: 110mA DC5V (PLC internal power supply), 90mA DC24V (external power supply).
Analog input points: 4 points.
Voltage input: DC-10~10V.
Current input: DC-20~20mA, 4~20mA.
Weight: 0.2kg.
Dimensions: 55 x 90 x 87 MITSUBISHI PROGRAMMING MANUAL II.
Voltage input and current input of 4 channels can be carried out,
Each channel can be specified as a current input or voltage input.
Built in digital filter function and peak hold function, etc.,
Achieved a high speed of 500 AD S/ch conversion.
FX3U-4AD can connect FX3GA/FX3G, FX3GE, FX3U series MITSUBISHI PROGRAMMING MANUAL II.
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-IPS-5V. Power: 185kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the motor power used to select AC reactor MITSUBISHI PROGRAMMING MANUAL II.
(when the inverter capacity is greater than the motor capacity, is still based on the mmotor capacity to choose FX1S-10MR-ES/UL PROGRAMMING MANUAL II. ) Enter 32 points or 32 points;
Divided into 16 points, 16 points out of the output.
Directly connected to the input and output terminals of PLC;
Can play a role in replacing the terminal row;
Can alsoo be far away from the PLC of the site when the input and output devices;
Use as relay;
In order to reduce the time of the input and output connection FX1S-10MR-ES/UL Manual.