Analog output expansion board (1 channel).Cable length: 0.2 meters.
QCPU/L02SCPU (-P) RS-422 cable (GT01-C / R4-25P, GT10-C / R4-25P, GT21-C / R4-25P5) FX1S-14MT-ES/UL PDF.
L6ADP-R2 RS-422 (GT01-C cable - R4-25P GT10-C - R4-25P, GT21-C -, R4-25P5).
[MINI-DIN 6 pin D-sub 25 pin].
Applicable models: GT27, GT25, GT23, GT21. Extension board for connection with special adapters
(FX1S and FX1N host general)
FX1S-14MT-ES/UL Max input / output points: 32 points.
Power supply voltage: 24VDC.
Input points: 16 points.
Output points: 16 points.
Output type: Transistor (source).
Power consumption: 25w.
Weight (kg):0.65.
Size (WxHxD) mm:150x90x87 FX1S-14MT-ES/UL PDF.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit FX1S-14MT-ES/UL PDF.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate MITSUBISHI HARDWARE MANUAL FX1S-14MT-ES/UL Manual.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard MITSUBISHI HARDWARE MANUAL.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017). MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V MITSUBISHI HARDWARE MANUAL.
Frequency converter capacity: 355KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor.
Why is the frequency of the inverter voltage proportional to tthe change?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, the current is not allowed to exceed the rated value, otherwise it will cause the heating of the mmotor FX1S-14MT-ES/UL Manual FX1S-14MT-ES/UL HARDWARE MANUAL.
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity.