Power: 15kw.
Voltage: 200V.
The power factor of the input power factor is up to 0.99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode FX1S-30MT-DSS PDF.
Equipped with standard power retrogradation function. Input / output form: relay output.
Output points: 8 points.
Input and output points: 8 points.
Because all models of FX series are built in high speed counter,
So the high speed control can be realized by the simple procedure
FX1S-30MT-DSS
The input of the basic unit is built in the anti jitter filter,
One part as digital filter,
Sensitivity adjustment unit can reach 1ms.
Using high speed counter automatically adjusted to the minimum value FX1S-30MT-DSS PDF.
Through the high cost of the built-in positioning function and the expansion function to increase the number of control axis.
Extended function expansion board and special adapter,
Data links and communication with extternal serial devices FX1S-30MT-DSS PDF FX1S-30MT-DSS Manual.
FX2N extension module.
The expansion module is an input and output expansion device of the power supply from the basic unit or the expansion unit,
Can choose the relay or crystal output models, to 8 points for the unit to connect.
Can be extended to FX3GA/FX3G, FX3GE, FX3GC, as well as FX3U, FX3UC series,
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-1PS-5V MITSUBISHI PROGRAMMING MANUAL II.
The number of connection points depends on the basic unit and the expansion unit. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 5.5KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) MITSUBISHI PROGRAMMING MANUAL II MITSUBISHI PROGRAMMING MANUAL II.
Starting with power frequency power supply, the starting current is 6~7 times of the rrated current, therefore, the impact on the mechanical and electrical FX1S-30MT-DSS PROGRAMMING MANUAL II.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120%% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load FX1S-30MT-DSS Manual.