Enter 32 points or 32 points;
Divided into 16 points, 16 points out of the output.
Directly connected to the input and output terminals of PLC;
Can play a role in replacing the terminal row;
Can also be far away from the PLC of the site when the input and output devices;
Use as relay;
In order to reduce the time of the input and output connection FX1S-30MT-ESS/UL PDF. Max input / output points: 48 points
FX1S-30MT-ESS/UL
Power supply voltage: 24VDC.
Input points: 24 points.
Output points: 24 points.
Output type: transistor.
Power consumption: 30W.
Weight (kg):0.85.
Size (WxHxD) mm:182x90x87.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard FX1S-30MT-ESS/UL PDF.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Note recording function, Component annotation can be recorded in the program register FX1S-30MT-ESS/UL PDF.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program executtion faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications MITSUBISHI HARDWARE MANUAL FX1S-30MT-ESS/UL Manual.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K MITSUBISHI HARDWARE MANUAL.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type) MITSUBISHI HARDWARE MANUAL.
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable. Power: 55kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-AA820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity FX1S-30MT-ESS/UL HARDWARE MANUAL.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motorr power used to select the DC reactor FX1S-30MT-ESS/UL Manual.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.)