Power: 22kw.
Voltage: 400V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control FX3G-14MT/ESS PDF.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and reduce the comprehensive cost.
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving
FX3G-14MT/ESS Analog output expansion board (1 channel).
Can be installed in FX1N, PLC FX1S, providing 1 channel analog input of the board.
Because it is embedded in the PLC installation, so do not need to install space FX3G-14MT/ESS PDF.
Can easily control the speed of the inverter. Convert connectors to fast connectors.
According to the location of the connection equipment distribution module. The built-in I/O function (Location: 1 axis) of the pulse output is converted to a differential drive output FX3G-14MT/ESSS PDF FX3G-14MT/ESS Manual. Protocol: SLMP, TCP/IP, UDP.
Communication mode: full duplex / half duplex.
At the same time can open a few: 4 connection.
Weight: 0.3kg.
Connect PLC FX3U/FX3UC to Ethernet.
Support fixed buffer storage, communication connection MELSOFT, through the MC communication protocol, e-mail messages MITSUBISHI USER'S MANUAL.
When connected to the MELSOFT, through the Works2 PLC can achieve the remote maintenance of GX program.
Connecting FX3UC, FX3GC requires FX2NC-CNV-IF or FX3UC-IPS-5V. MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 90kw.
SLD converter rated current: 475A MITSUBISHI USER'S MANUAL.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection MITSUBISHI USER'S MANUAL.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment) FX3G-14MT/ESS USER'S MANUAL.
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network FX3G-14MT/ESS Manual.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps.