CC-Link interface module.
PLC FX can be used as the CC-LINK remote device station connection.
If using CC-LINK type FX2N-16CCL-M system master module,
So just PLC CC-LINK can build FX system FX3G-40MR/DS PDF. Length: 1.5m.
Specification: TB-FX round cable. "Power: 15kw.
Voltage: 200V.
Brake resistor, a kind of ripple resistance, is mainly used in the mechanical system of the inverter to control the speed of the motor,
Help the motor to be converted into heat energy due to the regenerative power of the motor
FX3G-40MR/DS
Braking unit principle: the brake unit is composed of a high power transistor GTR and its driving circuit FX3G-40MR/DS PDF.
Its function is to link the discharge current braking resistor capacitor voltage or not in the range of the time consumed and the DC part "overpressure",
Need to add external braking componentss, in order to speed up the speed of the consumption of renewable energy FX3G-40MR/DS Manual. "Function extension for connection to special adapters FX3G-40MR/DS PDF.
DC5V power consumption: 0mA. Power: 185kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the motor power used to select AC reactor MITSUBISHI USER'S MANUAL.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 0.75KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) MITSUBISHI USER'S MANUAL.
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical MITSUBISHI USER'S MANUAL FX3G-40MR/DS USER'S MANUAL.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120%% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load FX3G-40MR/DS Manual.