LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI FX3U-16MT/ES-A PROGRAMMING MANUAL (Basic & Applied Instructions Edition) PDF

MITSUBISHI FX3U-16MT/ES-A PROGRAMMING MANUAL (Basic & Applied Instructions Edition) PDF

Brand: MITSUBISHI
Product model: FX3U-16MT/ES-A
Name: PLC
Sort: PROGRAMMING MANUAL (Basic & Applied Instructions Edition)
File language: English
File size: 16.77MB
"MITSUBISHI inverter FR-E720S series.
Voltage level: single phase 200V.
Frequency converter capacity: 0.75KW.
The use of frequency converter motor is in order to speed, and reduce the starting current FX3U-16MT/ES-A PDF.
In order to produce a variable voltage and frequency, the device is the first power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter) FX3U-16MT/ES-A
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter FX3U-16MT/ES-A PDF.
Inverter output waveform is simulated sine wave, mainly used in three-phase asynchronous motor speed control, and also called frequency governor. "Power: 3.7kw.
Purpose: high frequency braking resistor FX3U-16MT/ES-A PDF.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utillization rate of the regenerative braking should be less than the allowable brake use rate in the above table MITSUBISHI PROGRAMMING MANUAL FX3U-16MT/ES-A Manual.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used. But please pay attention to the allowable brake use rate MITSUBISHI PROGRAMMING MANUAL.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor.
The installation of thermal relay, to avoid overheating and burn the braking resistor. MITSUBISHI inverter FR-E720 series.
Voltage level: 3 phase 200V MITSUBISHI PROGRAMMING MANUAL.
Frequency converter capacity: 7.5KW.
In order to ensure the reliability of production, all production machinery in the design of power with drive, there is a certain amount of surplus.
When the motor can not run under full load, in addition to meet the requirements of power driven,
The surplus torque increases the active power consumption, resulting in the waste of electric energy.
Speed control method of fan and pump equiipment traditional by regulating the entrance or exit of the baffle, valve opening to regulate air flow and water flow
, the input power is large, and a large amount of energy consumption in the baffle, the valve in the processs of closure FX3U-16MT/ES-A Manual FX3U-16MT/ES-A PROGRAMMING MANUAL.
When using variable frequency control, if the flow rate is reduced, the speed of the pump or fan can be reduced to meet the requirements.
Related products
MITSUBISHI
PLC
FX3G-40MT/ES-A
MITSUBISHI PLC FX3G-40MT/ES-A
Input points: 24 points. Output points: 16 po
MITSUBISHI
PLC
FX3U-48MT/ES-A
MITSUBISHI PLC FX3U-48MT/ES-A
Max input / output points: 48 points. Supply
MITSUBISHI
PLC
FX3U-64MT/ES-A
MITSUBISHI PLC FX3U-64MT/ES-A
Max input / output points: 64 points. Supply
MITSUBISHI
CC-Link connection module
FX3U-16CCL-M
MITSUBISHI CC-Link connection module FX3U-16CCL-M
Station type: Master station. Maximum numer