MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 30kw.
SLD converter rated current: 154A.
Structure and function: Standard model FX3U-4AD-PNK-ADP PDF.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection
FX3U-4AD-PNK-ADP
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment) FX3U-4AD-PNK-ADP PDF.
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps FX3U-4AD-PNK-ADP PDF. Total points: 14 points.
Inpput points: 8 points FX3U-4AD-PNK-ADP Manual.
Output points: 6 points.
Voltage: AC220V.
Output type: relay.
Outline dimension: 60*75*90.
MITSUBISHI FX1S series PLC is suitable for the smallest package,
It is the preferred target for low cost users to seek powerful control over a limited range of I/0 MITSUBISHI USER'S MANUAL.
FX1S provides up to 30 I/O points, and can be transmitted through serial communication data,
MT models also have the ability to locate, widely used in a variety of small mechanical equipment. Power: 22kw.
Purpose: to suppress the power harmonics MITSUBISHI USER'S MANUAL.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose MITSUBISHI USER'S MANUAL. ) Function extension board for RS-232C communication.
DC5V power consumption: 20mA. Analog input points: 4 points (type PT100 sensor).
Rated temperature range: -100~600 degree.
Effective digital output: -1000~6000.
Resolution: 0.2~~0 FX3U-4AD-PNK-ADP USER'S MANUAL. 3 degree.
Weight: 0.1kg.
Dimensions: 17.6 x 90 x 89.5.
Analog quantity input adapter for platinum temperature measuring resistor (PT100 3 wire) temperature sensor.
FX3U-4AD-PTW-ADP through 4 channels, can measure the degreee of -100~600 FX3U-4AD-PNK-ADP Manual.
No programming to send data to FX3 series.
Connect FX3SA, FX3S, FX3GA, FX3G, FX3U,
Need to convert adapter or function extension board.