MITSUBISHI FX3UC-16MT/DSS-P4 USER'S MANUAL (Positioning Control Edition) PDF

Brand: MITSUBISHI
Product model: FX3UC-16MT/DSS-P4
Name: PLC
Sort: USER'S MANUAL (Positioning Control Edition)
File language: English
File size: 5.86MB
Max input / output points: 10 points.
Power supply voltage: DC24V.
Input points: 6 points.
Output points: 4 points.
Output type: relay.
Power consumption (W): 19 FX3UC-16MT/DSS-P4 PDF.
Weight (kg):0.3.
Size (WxHxD) mm:60x90x75.
Positioning and pulse output functions: a PLC cell can output 2 point 100KHz pulses at the same time.
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute or relative address expression and special pulse output control FX3UC-16MT/DSS-P4
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device FX3UC-16MT/DSS-P4 PDF.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drivve servo or stepper motor FX3UC-16MT/DSS-P4 Manual.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O FX3UC-16MT/DSS-P4 PDF.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication. MITSUBISHI inverter FR-D720S series.
Voltage level: single phase 200V MITSUBISHI USER'S MANUAL.
Frequency converter capacity: 0.75KW.
VVVF frequency control, vector control frequency conversion, direct torque control is a kind of AC - DC - AC frequency conversion.
The common drawback is that the input power factor is low, the harmonic current is big, and the DC circuit needs large energy storage capacity,
Renewable energy and can not be fed back to the power grid, which can not be carried out in the four quadrant operation MITSUBISHI USER'S MANUAL. To this end, the matrix type of AC - AC variable frequency arises at the historic moment.
Because the matrix type alternating current frequency saves the intermediate DC link, thereby, the electrolytic capacitor with large volume and high price can be omitted MITSUBISHI USER'S MAANUAL FX3UC-16MT/DSS-P4 USER'S MANUAL.
It can achieve a power factor of L, the input current is sinusoidal and can run in four quadrant, the power density of the system is large.
Although the technology is not yet mature, but still attract a large number of scholars in-depth study FX3UC-16MT/DSS-P4 Manual.
In fact, the quality is not the indirect control current, flux, but the torque is directly used as the control to achieve.
Related products
MITSUBISHI
PLC
FX3UC-16MT/DSS-P4
MITSUBISHI PLC FX3UC-16MT/DSS-P4
Input and output points: 16 points. Input poi
MITSUBISHI
PLC
FX3UC-16MT/D-P4
MITSUBISHI PLC FX3UC-16MT/D-P4
Input and output points: 16 points. Input poi
MITSUBISHI
PLC
FX3UC-16MR/D-T
MITSUBISHI PLC FX3UC-16MR/D-T
Input and output points: 16 points. Input poi
MITSUBISHI
PLC
FX3UC-16MT/DSS
MITSUBISHI PLC FX3UC-16MT/DSS
Input and output points: 16 points. Input poi