Transmission speed: 100Mbps/10Mbps.
MELSOFT connection.
SLMP cross letter (MC protocol).
Communication protocol support function.
E-mail function.
Web function L02CPU-CM PDF.
Collect / change CPU module data from the other side of the device.
SLMP (MC protocol) communication
SLMP is a protocol that uses Ethernet to access SLMP devices from the other device.
If it is possible to follow the SLMP control procedures to send and receive messages to the device,
The communication can be carried out by SLMP
L02CPU-CM MC can also support the previous agreement.
MELSOFT connection
Can be connected with the programming tool Works2 GX and other MELSOFT products L02CPU-CM PDF.
In addition, through the use of communication tools to support the sale of (MX Component),
Regardless of the details of the protocol (how to send and receive procedures),
Can create a communication program on the upper side of the system.
It can easily connect to BACnet and MODBUS /TCP
Communication protocol support function
Through the Works2 GX communication protocol support function, can easily set the communiication with the other equipment required for the agreement L02CPU-CM PDF L02CPU-CM Manual. Input points: 32 points.
Input voltage: DC24V.
Enter the public side of the way: 32 points / public MITSUBISHI Programming Manual.
Output form: transistor output (drain).
Output points: 32 points.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have
Output common way: 32 point / common.
Input / output occupied points: 32 points (I/O distribution: input and output mixed 32 points) MITSUBISHI Programming Manual.
External wiring connection: 40 pin connector two.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged MITSUBISHI Programming Manual.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge prottection function, with 3000V photoelectric isolation L02CPU-CM Programming Manual.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convennient and flexible L02CPU-CM Manual.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability.