DC5V internal consumption current: 0.08A.
Weight: 0.13kg.
1 the field input interface module is composed of an optical coupling module and an input interface module of the microcomputer,
Function is the interface of the programmable logic controller and the field control L02CPU-P PDF.
2 the field output interface module is integrated with the output data register, the gating module and the interrupt request module,
The programmable logic controller outputs the corresponding control signal to the execution part of the field through the field output interface module
L02CPU-P "Universal output function: source type L02CPU-P PDF.
Program capacity: 20K step.
Basic operations processing speed: 60ns.
Communication interface: USB/RS-232.
Control mode: stored procedure repeated operation.
Input / output points: 1024 points.
End cap.
Unable to install display module (L6DSPU-C-CM), RS-232 adapter, RS-422/485 adapter.
CPU built-in functions can be easily set through programming tools L02CPU-P PDF.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement MITSUBISHI Programming Manual.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ".
High precision PWM control of the highestt 200kHz L02CPU-P Manual .
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s MITSUBISHI Programming Manual.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators. "Number of input channels: 4ch MITSUBISHI Programming Manual.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 40 s/2ch.
Resolution: 1/32000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth continuoous analog output L02CPU-P Programming Manual.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period L02CPU-P Manual .
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.