Maximum transmission speed: 115.2kbps.
DC5V internal consumption current: 0.02A.
GOT connection.
MELSOFT connection.
Communication protocol support function serial communication function L06CPU-CM PDF. Thermocouple input.
Number of input channels: 4ch.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function
L06CPU-CM
Temperature input mode.
Temperature regulation mode.
To achieve high stability temperature control
Standard control / heating, cooling control.
The device used for the temperature control of the temperature control of the extrusion molding machine can prevent over heating and cooling L06CPU-CM PDF.
According to the object device can choose any one of the following control method.
Standard control (heating or cooling).
Heating, cooling control (heating and cooling).
Hybrid control (combination of standard control and heating, cooling control) L06CPU-CM PDF.
To reduce operating costs by saving energy
Peak current suppression
After the peak current suppression function is used, the number off the upper limit output limit of each channel can be changed automatically,
Split transistor output time L06CPU-CM Manual. To suppress the peak current MITSUBISHI User's Manual.
Restrain the peak current to achieve energy saving effect (reducing the power supply capacity of the equipment, saving the electricity contract), and reduce the operation cost.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function MITSUBISHI User's Manual.
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion.
No idle running, with energy saving effect, can reduce operating costs. RS-232.
Transmission speed: 230.4kbps.
MC protocol.
Communication protocol support function MITSUBISHI User's Manual.
Can only be used on the ch1 side.
Device for immediate communication
Communication protocol support function through Works2 GX,
Can easily set the required agreement with the other equipment communication.
In addition, only the communication protocol library is required to select the equiipment to be carried out,
Immediate connection L06CPU-CM User's Manual.
The creation and editing of communication protocols are simple and easy to implement, even if there is no connection equipment in the communication protocol library,
Can also simply crreate a corresponding protocol for communication L06CPU-CM Manual.
The content of the communication protocol that can be created in the list,
Can also be simply edited.