Differential output.
Axis of control: 1.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis.
Max link distance: 10m.
Start is also simple L06CPU-P PDF.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period.
Waveform display, you can improve the efficiency of the start.
The use of steps in accordance with the auxiliary function can be
L06CPU-P
Can be set by different uses of the probe, easy to view the data set.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 8CH, bit 8CH data can be displayed in real time L06CPU-P PDF.
Monitoring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check.
Can only choose the necessary items from the rich monitoring information and monitor the display.
Through the test function, do not have to control procedures can also be implemented to confirm the basic action L06CPU-P PDF. Control axis: maximum 4 axes.
Operation cycle: 0.88ms.
Interpolation function: linear interpolation (maximum 4 axis), 2 axis arc interpolation.
Color signal: 4 points.
Color detecting set: 4 set.
Only need to use the PLC program can easily achieve synchronous control, cam control, speed and ttorque (push pressure control) and other advanced motion control MITSUBISHI Programming Manual L06CPU-P Manual.
Equipped with standard synchronous encoder and color detection function necessary function.
Can be no procedures for setting. Strong support for MELSOFT.
Can fully apply LD77MH of the old program MITSUBISHI Programming Manual.
Let motion control more simple. Output channel number: 4ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA.
Conversion speed: 20 s/ch.
Resolution: 1/20000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm MITSUBISHI Programming Manual.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth continuuous analog output L06CPU-P Programming Manual.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period L06CPU-P Manual.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.