Output points: 16 points.
Output form: source type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.5A/1 point.
Protection function: have.
Common way: 16 point / public end L06CPU-P PDF.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called
L06CPU-P
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch L06CPU-P PDF.
Communication protocol is a standard Modbus protocol or custom protocol. Cable length: 0.6m.
Weight: 0.19kg.
Definition 1: conductor by one or a plurality of mutually insulated and insulating protective layer made of,
A conducttor of electricity or information from one place to another L06CPU-P PDF L06CPU-P Manual.
Definition 2: usually by a few or several groups (each with at least two wires) cable rope twisted the similar,
Each group of wires are insulated from each other, and are often twisted around a center,
The entire outer bread has a highly insulated cover MITSUBISHI Programming Manual.
The cable has the characteristics of internal power and external insulation. DB A20 AnyWire master station.
Transmission distance: the longest 3km.
Data input and output: up to 1024 points.
Connect up to 128 units.
Enter 512 points, 512 points out of the output.
Support environmental protection, high speed, long distance transmission and special distribution system to support the special flat cable, universal VCTF cable, universal single wire cable and other cable MITSUBISHI Programming Manual.
Using original transmission mode, there is almost no branch limit,
Supports the automatic track and ring transmission,
Can also create suitable for small and medium sized factory wiring system MITSUBISHI Programming Manual.
Support remote I/O, analog quanttity, temperature and humidity terminal, anti false operation terminal and other equipment L06CPU-P Programming Manual.
Up to 128 units from the station module
Can connect up to 128 units from the station module, for up to 1024 points (input 512 points / outputt 512 points) of the I/O control L06CPU-P Manual.
In addition, the parameters can be set through the switch, easy to set the transmission distance of 50m/200m/1km/3km.