SSCNET III /H remote station.
Transmission speed: 150Mbps.
End cap.
Play the role of SSCNET III /H remote station
SSCNET III /H host module is the MELSEC-L series of input and output modules and intelligent function modules connected to the SSCNET III /H module L26CPU-BT-CM PDF.
Can be used as a remote station of motion controller,
The flexible configuration of I/O module and intelligent function module is realized,
Reduce device wiring, save space
L26CPU-BT-CM
In addition, the module can be used for the input and output of the motion controller by the circulating transmission, and the module of the SSCNET III /H host module can be installed L26CPU-BT-CM PDF. Display characters: 16 x 4 character line width.
Display character: English letters and numbers (full / half), Katakana (full / half), hiragana (angle), (angle), symbol Chinese characters (full / half).
Language switch: Chinese / english.
Backlight display: green (normal), red (abnormal) L26CPU-BT-CM PDF.
Weight 0.03kg. Control axis: maximum 16 axes.
Operation cycle: 0.88ms, 1.77ms.
Interpolation function: linear interpolation (maximum 4 axis), 2 axis arc interpolation.
Color signal: 4 points.
Color detecting set: 16 set.
Only need to use the PLC program can easily achieve synchronous control, cam control, speed and torque (push pressure control) and other advanced motion control MITSUBISHI Programming Manual.
Equipped with standard synchronous encoder and color detection function necessary function.
Can be no procedures for setting. Strong support for MELSOFT.
Can fully apply LD77MH of the old program MITSUBISHI Programming Manual.
Let motion control more simple. Thermocouple input.
Number of input channels: 4ch.
Detection function of broken wire with heater.
Standard control.
Heatinng and cooling control L26CPU-BT-CM Manual .
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode MITSUBISHI Programming Manual.
Temperature regulation mode.
To reduce operating costs by saving energy
Peak current suppression
After the peak current suppression function is used, the number of the upper limit output limit of each channel can be changed automatically,
Split transistor output time. To suppress the peak current.
Restrain the peak current to achieve energy saving effect (reducing the power supply capacity of the equipment, saving the electricity contract), and reduce the operation cost.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion.
No idle running, with energy saving effect, can reduce operating costs.
To achieve high stability temperature control
Standard control / heating, cooling control.
The device ussed for the temperature control of the temperature control of the extrusion molding machine can prevent over heating and cooling L26CPU-BT-CM Programming Manual.
According to the object device can choose any one of the following control method.
Standard controol (heating or cooling) L26CPU-BT-CM Manual .
Heating, cooling control (heating and cooling).
Hybrid control (combination of standard control and heating, cooling control).