LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI L26CPU-PBT Programming Manual (Application Functions) PDF

MITSUBISHI L26CPU-PBT Programming Manual (Application Functions) PDF

Brand: MITSUBISHI
Product model: L26CPU-PBT
Name: PLC
Sort: Programming Manual (Application Functions)
File language: English
File size: 5.25MB
Open collector output.
Axis of control: 1.
Maximum output pulse: pulse/s 200k.
Location data: 600 data / axis.
Max link distance: 2m.
With the parameter setting, the synchronization control can be easily realized L26CPU-PBT PDF. Do not need to write complex procedures.
Start / stop with synchronous control of the shaft.
Synchronous control of the axis and the positioning of the axis can coexist.
Through the clutch, the movement of the main shaft can be transferred to the output shaft L26CPU-PBT
Simple implementation of synchronization control.
Cam control is more simple
Cam data can easily create a variety of patterns L26CPU-PBT PDF.
Can be simple to achievve the gear, shaft, transmission, cam and other mechanical mechanisms to replace the software synchronization control L26CPU-PBT Manual.
It is not subject to the limitation of the concept of the electronic cam control so far, and can use the cam with high degree of freedom.
The stroke, speed, acceleration and beat can be confirmed on the graph, and the setting is carried out at the same time L26CPU-PBT PDF.
Can also be through the cam data thumbnail display, easy to confirm the cam data has been created.
Can import and export the cam data in CSV format. Input points: 16 points.
Rated input voltage: DC24V MITSUBISHI Programming Manual.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, correspoonding to the two input and output modules, multiple input and output modules, and so on MITSUBISHI Programming Manual MITSUBISHI Programming Manual L26CPU-PBT Manual L26CPU-PBT Programming Manual.
Related products
MITSUBISHI
cpu module
L26CPU-CM
MITSUBISHI cpu module L26CPU-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L26CPU-BT-CM
MITSUBISHI cpu module L26CPU-BT-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L26CPU-P
MITSUBISHI cpu module L26CPU-P
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L26CPU-PBT
MITSUBISHI cpu module L26CPU-PBT
"Universal output function: source type. Prog