MITSUBISHI ME96NSR-MB Interface specifications PDF

Brand: MITSUBISHI
Product model: ME96NSR-MB
Name: ELECTRONIC MULTI-MEASURING INSTRUMENT
Sort: Interface specifications
File language: English
File size: 1.33MB
Content: CNP2 connector two.
Purpose: MR-JE-200B to MR-JE-300B, MR-JE-200A to MR-JE-300A with. The length of the line: 2M.
IP level: IP65.
Cable lead out direction: motor shaft different side ME96NSR-MB PDF.
Bending life: standard.
The cable is not shielded.
Encoder with cable (motor side); for HF-KP/HF-MP series (motor shaft with side extraction). MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series ME96NSR-MB
Rated output: 7.0kw.
Interface type: SSCNET type III fiber communication.
Full closed loop control.
Power specification: three phase AC200V.
High precision and high response location control.
Full closed loop control can be realized by double feedback control method ME96NSR-MB PDF.
Dual feedback control can be performed between the servo motor encoder and the load side encoder.
MR-J3-B-RJ006 can be used in conjunction with a number of manufacturers of linear encoder,
Users can build the system according to their own accuracy requirements ME96NSR-MB PDF ME96NSR-MB Manual. ABS type linear encoder using serial interface,
No need to install the battery on the servo amplifier can easily build the absolute position detection system.
Flexible system configuration.
Can achieve higher load side positioning accuracy!MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series MITSUBISHI Interface specifications.
Rated output: 22.0kw.
Interface type: SSCNET type III fiber communication.
Special features: integrated driver security.
Power specification: three phase AC400V.
STO function as a security feature is added to the SSCNET III fiber communication type servo amplifier MITSUBISHI Interface specifications.
By using the STO function, the electromagnetic contactor used in the past to prevent the motor from accidentally starting is no longer needed.
SS1 functions can be realized by using the MR-J3-D05 security logic unit.
MR-J3-BS uses a full closed loop control system.
Compatibility with MR-J3-B.
MR-J3-BS installation, wiring and connectors aree the same as the MR-J3-B, so do not change the existing connection will be easy to MR-J3-B
Change to MR-J3-BS MITSUBISHI Interface specifications ME96NSR-MB Interface specifications.
Security functions are connected to the CN8 interface through an external securityy circuit to increase the MR-J3-BS driver security ME96NSR-MB Manual.
Compatible full closed loop control system.
MR-J3-BS has a full closed loop control system version.