Master / local station sharing.
IE CC-Link field network.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module Q00CPU PDF.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update
Q00CPU Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX Q00CPU PDF.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation.
QJ71GF11-T2 can be used as the main station / local station of IE CC-Link field network Q00CPU PDF. Output points: 16 points.
Minimum load voltage and current: 25mA; AC24V<100mA/AC240V.
Leakage current: 1.5mA OFF (AC120V) 3mA (AC240V);
Response time: 1ms+0.5Hz.
16 points and 1 common ends.
18 point terminal station.
With the surge absorber.
Continue to go beyond, to climb the peak of Q series MITSUBISHI Programming Manual.
Strengthenn security function Q00CPU Manual.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users MITSUBISHI Programming Manual.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module MITSUBISHI Programming Manual.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.
Easy connection programming tool via ethernet.
Programming tools (WWorks2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings Q00CPU Programming Manual. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method annd the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection Q00CPU Manual.