AC input: 32 points.
Rated current and voltage: AC100 ~ 120V, 10mA (AC100V, 60Hz).
Response time: 25ms.
Input form: 1 points, 32 public ends.
External wiring connections: 38 terminals (terminals sold separately) Q00JCPU-E PDF.
Replacement model: AX11.Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel
Q00JCPU-E
18 point terminal station.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling Q00JCPU-E PDF.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected Q00JCPU-E PDF.
Peak current suppression.
Can prevennt the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost Q00JCPU-E Manual.
Heating function at the same time MITSUBISHI Programming Manual.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced MITSUBISHI Programming Manual. SI/QSI/H-PCF/ broadband H-PCF optical cable.
Double circuit.
Remote I/O network (remote I/O station).
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station MITSUBISHI Programming Manual.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance bettween stations, the length of the total cable length, strong anti-interference Q00JCPU-E Programming Manual.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system Q00JCPU-E Manual. ..... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.