GI-62.5/125 optical cable.
Double ring.
Remote I/O net (remote I/O station).2 axes, open collector output type.
2 axis linear interpolation.
2 axis interpolation Q00JCPU-E PDF.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
Maximum pulse output: 200Kpps.
40 pin connector.
Positioning module.
Open collector output.
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types
Q00JCPU-E
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control Q00JCPU-E PDF.
(the command pulse of the open collector positioning module is highest 200kpps.)
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module Q00JCPU-E PDF.
Can fully meet the switch, sensor, such as the input and ooutput, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields MITSUBISHI Reference Manual Q00JCPU-E Manual.
Can also be used in combination with the CPU module to achieve appropriate control.
The possibility of expanding control with intelligent function.
Providing a variety of analog modules, is the ideal choice for process control applications.
Can also meet the needs of high speed, high precision control MITSUBISHI Reference Manual.
Most suitable analog modules for high speed conversion control.
Can provide a variety of analog and digital analog conversion module products.
These modules have a variety of functions, in the connection of equipment, to achieve the greatest flexibility.
Can meet the inverter control, such as high-speed conversion needs MITSUBISHI Reference Manual. Application: extension.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1.
Security input points: 1.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of coomponents can be easily and quickly set the hardware structure Q00JCPU-E Reference Manual.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connecttion settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file Q00JCPU-E Manual.