LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q00JCPU Programming Manual (Structured Text) PDF

MITSUBISHI Q00JCPU Programming Manual (Structured Text) PDF

Brand: MITSUBISHI
Product model: Q00JCPU
Name: PLC
Sort: Programming Manual (Structured Text)
File language: English
File size: 4.20MB
8 channel.
Input: DC4~20mA.
Output (resolution): 0~6400; 0~3200.
Conversion speed: 10ms/ channel.
18 point terminal station.
Isolation between channels Q00JCPU PDF.
Power supply to a two wire transmitter.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark Q00JCPU
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output Q00JCPU PDF.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
No external isolation amplifier required Q00JCPU PDF.
Without the use of inter channell isolation analog modules Q00JCPU Manual .
Using the inter channel isolation analog module.PCI bus.
Support Japanese, English OS.
SI/QSI/H-PCF/ broadband H-PCF cable.
Dual loop controller network (control station / common station).
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module MITSUBISHI Programming Manual.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time MITSUBISHI Programming Manual.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation MITSUBISHI Programming Manual.
Province distribution network moddule in cabinet and device Q00JCPU Programming Manual.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Linkk/LT from the station does not need any parameter settings Q00JCPU Manual .
Only need to set up the transmission speed in the master module, you can use the remote I/O.
Related products
MITSUBISHI
CPU unit
Q2ACPU
MITSUBISHI CPU unit Q2ACPU
Input and output points: 512 points. Input /
MITSUBISHI
General high speed CPU
Q13UDVCPU
MITSUBISHI General high speed CPU Q13UDVCPU
Input / output points: 4096 points. Input / o
MITSUBISHI
Motion controller
Q170MSCPU
MITSUBISHI Motion controller Q170MSCPU
Control axis: up to 16 axes. Interpolation fu
MITSUBISHI
Programmable logic controller CPU
R120ENCPU
MITSUBISHI Programmable logic controller CPU R120ENCPU
Operation control mode: stored procedure repe