AC input: 32 points.
Rated current and voltage: AC100 ~ 120V, 10mA (AC100V, 60Hz).
Response time: 25ms.
Input form: 1 points, 32 public ends.
External wiring connections: 38 terminals (terminals sold separately) Q00JCPU-S8 PDF.
Replacement model: AX11.Output: 8 channels.
Input (resolution): 0~4000; -4000~4000; 0~12000; -12000~12000.
Output: 0~20mA DC.
Conversion speed: 80 s/1 channel.
18 point terminal station
Q00JCPU-S8
Can provide a variety of analog and digital analog conversion module products.
These modules have a variety of functions, in the connection of equipment, to achieve the greatest flexibility.
Can meet the inverter control, such as high-speed conversion needs Q00JCPU-S8 PDF.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields Q00JCPU-S8 PDF.
Can also be used in combination with the CPU module to achieve appropriate control.
Transformer isolation between power supply and output MITSUBISHI Programming Manual.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input moduule Q00JCPU-S8 Manual.
Isolated analog input module.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules MITSUBISHI Programming Manual.
Using the inter channel isolation analog module.
The possibility of expanding control with intelligent function.
Providing a variety of analog modules, is the ideal choice for process control applications.
Can also meet the needs of high speed, high precision control.
Most suitable analog modules for high speed conversion control MITSUBISHI Programming Manual. "2 axes, SSCNET III type.
2 axis linear interpolation.
2 axis arc interpolation.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
40 pin connector.
Through the SSCNET III cable connection to save wiring, the distance between the station up to 50m.
Absolute position system for determining the origin position is supported by the return data set operation.
In addition, the limit switch of the upper limit, the lower limit switch and the near point block signal input can be directly connected to the servo amplifier,
Thus greatly reducing the wiring requirements.
Easyy to achieve high speed, high precision positioning control Q00JCPU-S8 Programming Manual.
Support for multiple types of positioning control,
Including 2 ~ 4 axis 2 axis linear interpolation, circular interpolation, speed control and speed / position control, ppath switching control, constant speed control etc Q00JCPU-S8 Manual. .
In addition, can use the "Configurator-QP GX" and other software,
Easy to set, monitor and debug. "